2G6
1-5-8
Code Error indications Contents
Check procedures/corrective measures
6000 Fuser unit error
Yes
Yes
Yes
No
No
Turn power switch off,
and remove power
cable.
Detach connector CN4
on power supply unit.
Detach connector CN1
on power supply unit.
Measure resistance
between pins 1 and 2
of the detached
connector.
Replace fuser thermistor.
See page 1-6-25.
Replace thermal cutout or
heater lamp. See page 1-6-
26 or 1-6-22.
Replace bias PWB (K0009)
or high voltage unit or power
supply unit. See page 1-6-13
or 1-6-12.
Open (infinite)?
No
No
Open (infinite)?
Measure resistance
between pins 1 and 3
of the detached
connector.
Replace harness
(2FM2601) between engine
PWB (K0010) and bias
PWB (K0009).
End.
Yes
No
Replace engine PWB
(K0010). See page 1-
6-9.
"6000" error
shown?
"6000" error
shown?
START