EasyManua.ls Logo

Learjet 60 - Flap Selector Switch; Flaps

Default Icon
408 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Learjet
60
Pilot's
Manual
FLAPS
The
hydraulically-actuated,
electrically-controlled
flap
system
pro-
vides
flap
settings of
UP
W),
8°,
20°,
and
DN
(40°)
.
The
single-slotted
flaps
are
attached
to the rear
wing
spar
with
tracks,
rollers,
and
hing-
es
.
The
flap selector
switch
controls
a
solenoid-operated
hydraulic
control
valve
that
meters
hydraulic
pressure
to
the flap
actuators
.
The
actuators
mechanically
rotate
sectors
attached
to
the
flaps
through
ad-
justable
push-pull
tubes
.
Interconnecting
cables
and
pulleys syn-
chronize
flap
movement
throughout
the
range
of
travel
.
A
flap
posi-
tion
switch
is
mechanically
connected
to
each
flap
sector
.
These
switches
provide
flap
position
information
to
the
landing
gear
warn-
ing,
stall
warning,
spoiler
warning,
trim-in-motion
warning,
spoile-
ron,
and
autopilot
systems
.
A
flap
limit
switch
is
mechanically con-
nected
to
each
sector to
automatically
maintain
flap
position
at
the
selected
setting
.
Overtravel,
when
the
flaps
are
fully
extended,
is
me-
chanically
prevented
.
The
flap
control
system
operates
on
28
VDC
supplied
through
the
3-amp
FLAPS
circuit
breaker
on
the
copilot's
circuit
breaker panel
.
The
flaps are
operative
during
the
EMER
BUS
mode
.
FLAP
SELECTORSWITCH
The
flap selector
switch
is
located
on
the
right
side of the
pedestal
near
the
thrust levers
.
The
switch
has
four
positions
:
UP,
8,
20,
and
DN
.
The
switch handle
is
shaped
like
an
airfoil
.
When
or
20°
flaps
is
selected,
28
VDC
is
directed
to
the
applicable
(up
or
down)
sole-
noid
of
the
flap
control
valve
.
The
flap
control
valve
will
meter
hy-
draulic
pressure
to
the
flap
actuators
and
move
the
flaps
in
the
de-
sired
direction
.
As
the
flaps
approach
within
of
the
selected
setting,
the
applicable
flap
limit
switch
will
remove
power
from
the
flap
con-
trol
valve
solenoid
and
flap
travel
will
stop
.
When
UP
is
selected,
28
VDC
is
directed
to the
up
solenoid
of
the flap
control
valve
and
the
flaps will
move
in the
up
direction
.
When
DN
is
selected,
28
VDC
is
directed
to
the
down
solenoid
of
the
flap
control
valve
and
the flaps
will
move
in
the
down
direction
.
When
the flaps
reach
full
extension,
the
"down"
pressure
will
remain
to
maintain
the
flaps
full
down
.