PARTIAL
position
of
the
Refuel
Selector
switch
is
used
to
fill
the
wings
first
and
then
the
fuselage
.
This
is
useful
when
full
wings and
less
than
full
fuselage
fuel
is
desired
.
When
PARTIAL
is
selected
and
the
vent
valve
opens,
the
fuselage
tank
solenoid
valve
will
be
con-
trolled
by
the
wing
high-level
float
switches
.
When
the
wings
are
full,
the
wing
high-level
float
switches
complete
the
circuit
to
open
the
fu-
selage
tank
solenoid
valve
.
When
the
solenoid
valve
opens,
the
fuse-
lage
tank
shutoff
valve
will
open
and admit
fuel to the
fuselage
tank
.
SPPR
BATT
SWITCH
The
BATTON-OFF
switch,
on
the
refuel
control
panel,
allows
opera-
tion
of
the
single-point
pressure
refuel
system
without
the
need
to en-
ter
the
cockpit
in
order
to
energize
aircraft
power
.
When
the
switch
is
set to
ON,
DC
power
from
the
aircraft's
#2
battery
is
applied
to
the
SPPR
control
circuits
.
FUS
FULL
LIGHT
The
amber
FUS
FULL
light,
on
the refuel
control
panel,
will illumi-
nate
whenever
the
fuselage
tank
float
switch
actuates
.
The
light
illu-
minates
to
alert
the
operator
that
refuel
operations
should
have
auto-
matically
terminated
.
If
fuel
flow
continues
with
the
light
illuminated,
fueling
operations
should
be
immediately
terminated
.
VENT
OPEN
LIGHT
The
green
VENTOPEN
light,
on
the refuel
control
panel,
will
illumi-
nate
whenever
the
fuselage
tank
vent
valve
opens
.
The
light
is
operat-
ed by
a
microswitch
in
the
valve
.
The
circuit
for
the
fuselage
tank
so-
lenoid
valve
is
wired
through
this
switch
to
prevent
filling
the
fuselage
tank
until
the
vent
valve
opens
.