EasyManua.ls Logo

Learjet 60 - Page 274

Default Icon
408 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Learjet
60
Pilot's
Manual
Following
actuation,
the
hood
will
inflate
over
a
15-20
second
period
.
After
this
period,
the
starter
candle
will
cease
flowing
and
the
only
sound
will
be
slight
rustling of the
fabric
on
each
inhalation
and
exha-
lation
.
Dependent
upon
breathing
rate,
there
will
be
a
slight
exhala-
tion resistance as the
exhaled
breath
is
forced
through
the
oxygen-
generating
canister
.
Inhalation
resistance will
be
almost unrecogniza-
ble since
inhalation
is
directly
from
the
interior
of the
hood
through
a
diaphragm
type
check valve
located
at
the
base
of
the
oronasal
mask
.
The
visor
should
remain
clear
of
fogging
or
misting
.
Heat
is
produced
by
both
the
chemical
air
regeneration
process
and
transfer
of
body
heat
during
the
rebreathing
cycle
.
Heat
build-up within
the
hood
is
normal and
is
dependent
upon
the
amount
of
work
performed
.
There
should
be
no
irritating
or
strong
unusual
odors
within
the
hood
.
Op-
erational
duration
is
variable
dependent
upon
the
amount
of
work
performed
by
the
user
.
If
the
PBE
is
worn
to
exhaustion
of
the
chemical
regeneration
system,
this
will
be
evidenced
by
a
gradual
reduction
in
the
expended
volume
of
the
hood
until
the
point
that the
hood
is
collapsed
tightly
around
the
head
at
the
end
of
a
full
inhalation
.
Additionally,
there
will
be a
rapid
buildup
of
heat
and
moisture
in
the
hood
as
the
canister
looses
its
effectiveness
.
At
this
point, the
wearer
should
immediately
retire
to a safe
breathing
area
clear
of
flame
and
toxic
fumes and
remove
the
device
.
Removing
the
PBE
:
1
.
Go
to
a
safe
area
away
from
immediate
contact
with
fire
or
open
flame
and/or
toxic
fumes
.
2
.
With
both
hands,
reach
for
the
two
lower
corners
of
the
visor
area
and
push
forward
on
the
metal
tabs
of the
adjustment
strap
buckles
to
release
the
strap
tension
.
3
.
Place
both
hands
under
the
neckseal
in
forward
area
and
pull
up,
guiding
the
oronasal
cone
and
neckseal
over
the
face/
glasses
until
the
PBE
is
clear
of
the
head
.
4
.
Place
the
expended
PBE
in a safe
place
to cool
away
from
fire
or
exposure
to
water
.
Disposal
:
The
expended
PBE
still
contains
unreacted
oxidizing
material
and
strong
alkali
materials
.
At
the
completion
of
flight,
it
must
be
turned
over
to
maintenance
for
authorized
disposal
.
PM-123
7-
1 3
Change
2

Table of Contents

Related product manuals