Six 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives, rear NVMe drive assembly and one 16i RAID
adapter
Note: The cable routing illustration is based on the scenario that the rear hot-swap drive cage is installed.
Depending on the model, the rear hot-swap drive cage might not be available on your server.
Figure 44. Cable routing for server model with six 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives, rear NVMe drive
assembly and one 16i RAID adapter
Note: RAID adapter can be installed in PCIe slot 1 or internal riser assembly.
Cable
From To
1 NVMe signal cable for front
backplane
NVMe 2 and NVMe 3 connectors on
the front backplane
PCIe connector 2 on the system
board
2 NVMe signal cable for front
backplane
NVMe 0 and NVMe 1 connectors on
the front backplane
PCIe connector 1 on the system
board
3 NVMe signal cable for rear
backplane
NVMe connectors on the rear
backplane
PCIe connector 3 on the system
board
4 SAS signal cable for front
backplane
SAS 2 connector on the front
backplane
C2 connector on the RAID adapter
5 SAS signal cable for front
backplane
SAS 0 and SAS 1 connectors on the
front backplane
C0 and C1 connectors on the RAID
adapter