• When the SAS/SATA backplanes are connected to PCIe connectors on the system board, only SATA
drives are supported. No SAS drives are supported.
• The cable routing illustration is based on the scenario that the rear hot-swap drive cage is installed.
Depending on the model, the rear hot-swap drive cage might not be available fon your server.
Figure 48. Cable routing for server model with ten 2.5-inch SATA/NVMe drives and rear SAS/SATA drive assembly
Note: M.2 drive is not supported for this configuration.
Cable
From To
1 NVMe signal cable for front
backplane
NVMe 0–1 connector on the front
backplane
PCIe connector 1 on the system
board
2 NVMe signal cable for front
backplane
NVMe 2–3 connector on the front
backplane
PCIe connector 2 on the system
board
3 NVMe signal cable for front
backplane
NVMe 4–5 connector on the front
backplane
PCIe connector 3 on the system
board
4 NVMe signal cable for front
backplane
NVMe 6–7 connector on the front
backplane
PCIe connector 4 on the system
board
5 NVMe signal cable for front
backplane
NVMe 8–9 connector on the front
backplane
PCIe connector 5 on the system
board
6 SAS signal cable for front
backplane
SAS/SATA 0–3 and 4–7 connectors
on the front backplane
PCIe connector 6 on the system
board
Chapter 2. Server components 57