Figure 52. Cable routing for server model with ten 2.5-inch SAS/SATA/NVMe drives, rear SAS/SATA drive assembly,
middle NVMe drive assembly and one 16i RAID adapter-2
Cable From To
8 SAS signal cable for front
backplane
SAS/SATA 0–3 and SAS/SATA 4–7
connectors on the front backplane
C0 and C1 connectors on RAID
adapter in PCIe slot 1
9 SAS signal cable for front
backplane
SAS/SATA 8–9 connector on the front
backplane
C2 connector on RAID adapter in
PCIe slot 1
10 SAS signal cable for rear
backplane
SAS 0 connector on the middle
backplane
C3 connector on RAID adapter in
PCIe slot 1
Ten 2.5-inch NVMe drives, rear NVMe drive assembly and middle NVMe drive assembly
Notes: The cable routing illustration is based on the scenario that the rear hot-swap drive cage and middle
NVMe drive assembly are installed. Depending on the model, the rear hot-swap drive cage and middle NVMe
drive assembly might not be available on your server. For the following configurations without the rear hot-
swap drive cage or middle NVMe drive assembly, you can also refer to the illustration and table for the cable
routing.
• Ten 2.5-inch NVMe drives: Connect Cable
1 and Cable 2
• Ten 2.5-inch NVMe drives and rear NVMe drive assembly: Connect Cable 1 , Cable 2 , and Cable 5
• Ten 2.5-inch NVMe drives and middle NVMe drive assembly: Connect Cable 1 , Cable 2 , Cable 3 , and
Cable
4