Commissioning
Commissioning via the diagnosis terminal
Commissioning steps
6
l
143
EDS84DG752 EN 7.0
Keypad display Action
Par1 8400 motec
User menu
A Select the menu in the main menu using the navigation key.
B Change to the menu using the navigation key.
Load Lenze setting
C00002/1
A Use the left function key to change to the editing mode for C00002/1.
B Use navigation key to select the "1: On/Start" entry in the selection list.
C Use the right function key to accept the executed change and quit the
editing mode.
The load process may take a couple of seconds.
9. Enable inverter: Set RFR to HIGH potential.
By default, the RFR terminal is bridged (controller enable).
If the auto−start option "Inhibit at power−on" is activated in C00142 and the
controller is enabled at mains connection, the controller remains in the
"ReadyToSwitchOn" status. For changing to the "SwitchedOn" status, controller
enable must first be deactivated. Only when the controller is enabled again
afterwards, the status changes to "OperationEnabled":
If the autostart option "Inhibit at power−on" is deactivated in C00142, the status
directly changes from "ReadyToSwitchOn" to the "SwitchedOn" state and to the
"OperationEnabled" state after mains connection when the controller is enabled.
} Danger!
When the auto−start option "Inhibit at power−on" is deactivated, the motor
can directly start after power−on if the controller is enabled!
10. Select speed:
In the "Terminals 0" by selecting a voltage at the analog input or by selecting a
fixed setpoint via the digital inputs DI1/DI2.
In the "Keypad" control mode, the main speed setpoint and the control signals are
predefined via the following parameters:
Parameters Name Info Lenze setting
C00728/3 nMainSetValue_a Main setpoint for the application 100 % º reference
speed (C00011)
0.00%
C00727/3 bSetSpeedCcw Change of direction of rotation
"0": CW rotation
"1": CCW rotation
0
C00727/4 bJogSpeed1 Selection of fixed setpoint 1
"0": Main setpoint (C00728/3) active.
"1": Fixed setpoint 1 (C00039/1) active.
0
11. If required, adapt further parameters.
12. Save parameter settings with function key
safe against mains failure in the
memory module.