Technical data
General data and operating conditions
4
l
32
EDS84DG752 EN 7.0
Ambient conditions
Climatic
Storage
IEC/EN 60721−3−1 1K3 (−30 ... +60 °C)
Transport IEC/EN 60721−3−2 2K3 (−30 ... +75 °C)
Operation IEC/EN 60721−3−3 3K3 (−30 ... +55 °C)
Operation at 4 kHz: > +45 °C: Reduce the rated output current
by 2.5 %/°C.
Operation at 8/16 kHz: > +40 °C: Reduce the rated output
current by 2.5 %/°C.
Site altitude < 4000 m amsl
Above 1000 m amsl reduce the rated output current by
5 %/ 1000 m.
Pollution IEC/EN 61800−5−1 Degree of pollution 2
Mechanical
Vibration resistance (9.81 m/s
2
= 1 g)
Motor mounting
Germanischer Lloyd General conditions: Acceleration resistant up to 2 g
IEC/EN 60721−3−3 3M6
Wall mounting with
E84DZMAWE1
Germanischer Lloyd General conditions: Acceleration resistant up to 2 g
IEC/EN 60721−3−3 3M6
Mounting conditions
Mounting place
Motor mounting Standard
Wall mounting With optional wall adapter Ensure convection cooling in the
niches!
Mounting position
Wall mounting
0.37...3.0kW Vertically with cooling ribs
at the top, rotated,
horizontally
l Observe derating, see
Hardware manual
8400 motec (^ EDS84DG752)
l Arrangement of several
devices only to the sides, so
that the convection cooling
remains ensured!
4.0...7.5kW Optional