Technical data
General data and operating conditions
4
l
33
EDS84DG752 EN 7.0
EMC
Noise emission (in TN and TT systems)
Cable−guided
EN 61800−3
Motor mounting
0.37...1.5kW, f
ch
£8 kHz Category C1
2.2...3.0kW, f
ch
£4 kHz Category C1
4.0...7.5kW Category C2
Wall mounting and
Lenze system cable
£ 20 m
EN 61800−3 0.37...7.5kW, f
ch
£4 kHz Category C2
Wall mounting and
Lenze system cable
£ 10 m
EN 61800−3 0.37...7.5kW, f
ch
£8 kHz Category C2
Radiation EN 61800−3
0.37...1.5kW, f
ch
£8 kHz Category C1
2.2...7.5kW, f
ch
£8 kHz Category C2
Noise immunity (according to requirements of EN 61800−3)
Electrostatic discharge
(ESD)
EN 61000−4−2 8 kV with air discharge,
4 kV with contact discharge against housing
Radio frequency
Conducted EN 61000−4−6 150 kHz ... 80 MHz, 10 V/m 80 % AM (1kHz)
Interference
(housing)
EN 61000−4−3 80 MHz ... 1000 MHz, 10 V/m 80 % AM (1kHz)
Burst
Power terminals and
interfaces
EN 61000−4−4 2 kV/5 kHz
Signal interfaces EN 61000−4−4 1 kV/5 kHz
Control terminals EN 61000−4−4 2 kV/5 kHz
Surge
Power terminals EN 61000−4−5 1.2/50 ms,
1 kV phase/phase, 2 kV phase/PE
Control terminals EN 61000−4−5 1.2/50 ms, 1 kV
Operation on public
supply systems
EN 61000−3−2
EN 61000−3−12
The devices are intended for use in an industrial
environment. When being used on public network, additional
measures must be taken to limit the expected radio
interference. The compliance with the requirements for the
machine/plant is the responsibility of the manufacturer of
the machine or system!
Voltage deviations
Voltage dips EN 61800−3 Short mains voltage dips (comp. IEC 61000−2−1) can lead to a
switch−off of the motor.