EasyManua.ls Logo

Lenze i750 - Safe Torque off (STO)

Lenze i750
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safe torque o (S
TO)
This funcon corresponds to a "Stop 0" according to EN 60204.
The motor cannot generate torque and movements of the drive.
DANGER!
With the "Safe torque o" (S
TO) funcon, no "emergency switching o" in terms with
EN 602041 can be executed without addional measures. There is no electrical isolaon
between the motor and inverter and no service switch or maintenance switch!
Possible consequence: Death or severe injuries
"Emergency switching o" requires electrical isolaon, e. g. by a central mains contactor.
DANGER!
Automac r
estart if the request of the safety funcon is deacvated.
Possible consequences: Death or severe injuries
You must provide external measures according to EN ISO 138491 which ensure that the
drive only restarts aer a conrmaon.
DANGER!
The power supply is not safely disconnected.
Dea
th or serious injury due to electrical voltage.
Turn o the power supply.
Precondions
Moon c
aused by external forces must be prevented by addional measures such as
mechanical braking.
The restart must be set. See chapter "Restart". ^ 111
Funconal descripon
How to safely disconnect the drive:
1.A safety sensor requests the safety funcon.
2.The transmission of the pulse width modulaon is safely switched o by the safety unit.
The power drivers do not generate a rotang eld anymore.
3.The inverter switches to the STO acve device status (status word 0x6041, Bit15 = 0).
The motor is safely switched to torqueless operaon (STO).