Basic Safety - STO
Basic Safety - STO is part of the i75AExxxFxA product variant.
NOTICE
Overvoltage
Des
trucon of the safety component
▶
Make sure that the maximum voltage (maximum rated) at the safe inputs does not exceed
30 V DC.
DANGER!
With the "Safe torque o" (S
TO) funcon, no "emergency switching o" in terms with
EN 60204‑1 can be executed without addional measures. There is no electrical isolaon
between the motor and inverter and no service switch or maintenance switch!
Possible consequence: Death or severe injuries
▶
"Emergency switching o" requires electrical isolaon, e. g. by a central mains contactor.
Safe state
When the pulse width modulaon of the in
verter is switched o by the safety equipment, the
motor is rendered free of torque. The inverter switches to the device state "STO acve".
4Sa
fe torque o (STO) ^ 118
Electrical ins
tallaon
Funconal safety
Basic Safety - STO
73