DC-bus with r
egenerave power supply module
If regenerave energy is to be fed back into the AC system from a DC-bus connecon, a
regenerave power supply module can be used.
The DC power supply adapter E70AZEVE001 is required to connect the DC cable from the DC
output of the regenerave power supply module to the DC busbar system of i750.
A brake resistor can addionally be connected to the brake chopper of the regenerave power
supply module.
L1
L3
L2
=
~
AC
3
M M M M
...
G1 Gx
...
VR1
Z1
L1
L1
L3
L3
L2
L2
3
+UG -UG
2
+UG -UG
Z2
max. 50 A
}
Fig. 4: Basic circuit diagram: DC bus c
onnecon with regenerave power supply module E94ARNExxxx
Z1 Mains lter
Z2 DC power supply adapter
E70AZEVE001
VR1 Regenerave power supply module
G1...
Gx
Inverter
Typical c
ombinaons
Regenerave power
supply module
Mains-side
components
Supply Power recovery
Mains lter DC output
current
I
DC 100%
[A]
DC-supply power
P
DC 100%
[kW]
DC output
current
I
DC 100%
[A]
DC regenerave power
P
DC 100%
[kW]
400 V 480 V 400 V 480 V
E94ARNE0134 E94AZMR0264SDB
32 15.0 18.0 16 7.5 9.0
E94ARNE0134 E94AZMR0264LDB
E94ARNE0244 E94AZMR0474SDB
57 27 32.4 28.5 13.5 16.2
E94ARNE0244 E94AZMR0474LDB
Informaon on pr
oject planning
DC-bus connecon
DC-bus with regenerave power supply module
38