Technical data
St
andards and operang condions
Conformies and approvals
Conformies
CE
2006/42/EC Machinery Direcve only relevant for safety components
2011/65/EU RoHS Direcve
2014/30/EU EMC Direcve (reference: CE-typical drive system)
EAC
TP TC 020/2011
Eurasian conformity: Electromagnec compability of
technical means
TR TC 004/2011 Eurasian conformity: Safety of low voltage equipment
UKCA
S.I. 2008/1597 The Supply of Machinery (Safety) Regulaons 2008
S.I. 2012/3032
The Restricon of the Use of Certain Hazardous Substances in
Electrical and Electronic Equipment Regulaons 2012
S.I. 2016/1091 The Electromagnec Compability Regulaons 2016
S.I. 2021/745
The Ecodesign for Energy-Related Products and Energy
Informaon Regulaons 2021
Approvals
UL UL 61800-5-1
File No. E132659
For USA and Canada (requirements of the CSA 22.2 No. 274)
Protecon of per
sons and device protecon
Degree of protecon Data applies to operaonally ready mounted state and not in
wire range of terminals
EN EN IEC 60529 IP20 In the wire range of mains and motor partly IP10
UL
UL 50E Type 1 Protecon against accidental contact only
UL 61800-5-1 Open type Only in UL-approved systems
Insulaon resistance
Overvoltage category EN IEC 61800-5-1
II >2000 m amsl
III 0 … 2000 m amsl
Isolaon of control circuits
EN IEC 61800-5-1 Safe mains isolaon Double/reinforced insulaon
Leakage current
AC
EN IEC 61800-5-1
> 3.5 mA
Observe regulaons and safety instrucons!
DC > 10 mA
Protecve measures
Earth fault strength
Motor stalling protecon
Short-circuit strength
Overvoltage resistance
Motor overtemperature PTC or thermal contact, I²xt monitoring
EMC data
Operaon on public supply s
ystems
Mains current > 16 A ... ≤ 75
A
EN IEC
61000-3-12
With mains choke or mains lter When designed for rated power.
Noise emission
Category C2
EN IEC 61800-3 see rated data
Category C3
Noise immunity
EN IEC 61800-3 Requirements fullled
Technical data
St
andards and operang condions
Conformies and approvals
77