Safe brake control (SBC)
This funcon pr
ovides for a safe brake control by the inverter.
DANGER!
Use of non-safety-rated brakes
P
ossible consequence: Severe injuries or death.
▶
Only use safety-rated brakes with suitable safety-related parameters according to
EN ISO 13849‑1 and/or EN 62061or EN IEC 61508.
The internal test rate of the brake output (X106) restricts the request rate to
ma
x. 1 brake request/10 seconds.
An applicaon-dependent test rate of the connected brake reduces the request
rate accordingly.
Condions
•
The br
ake is connected to X106.
•
Brake funcon and monitoring of the brake control are controlled via X106. 4Motor
holding brake connecon ^ 63
•
Parameter 0x2820:023 and 0x2820:005:
-
Both parameters must be set to "0".
-
Other sengs are not compable with the SBC funcon.
The warning "Incompable SBC device conguraon - 0x6187" is output.
STO stop funcon is acvated.
Funconal sa
fety
Safety funcons
Safe brake control (SBC)
145