Preparaon
Further data and in
formaon for mechanical mounng:
4Control cabinet structure ^ 33
4Dimensions ^ 95
Installaon clearances
Maintain the specied installaon clearances above and below to the other installaons.
Several devices of the same series can be lined up directly, regardless of the device size. No
installaon clearance is required between the devices.
Mechanical installaon
The mounng locaon and material must ensure a durable mechanical connecon.
Do not mount onto DIN rails!
In case of connuous vibraons or shocks use vibraon dampers. If non-conducve
vibraon dampers are used, an EMC-compliant design must be ensured.
How to mount the inverters onto the mounng plate.
Precondions:
Mounng plate with conducve surface
Required:
Tool for drilling and thread cung
Screwdriver
Screw and washer assemblies or hexagon socket screws with washers.
1.Prepare mounng plate with corresponding threaded holes.
2.Fit screws and washers (if applicable).
3.Do not yet ghten the screws.
4.Mount the inverter on the prepared mounng plate via keyhole suspension.
5.Only ghten the screws hand-ght.
6.Pre-assemble further units if necessary.
7.Adjust the units.
8.Screw the units onto the mounng plate.
The inverter and any other units are mounted on the mounng plate. You can begin with the
wiring.
Screw and washer assemblies or hexagon socket screws with washers are recommended..
M5 x ≥ 10 mm for devices up to and including 2.2 kW
M5 x ≥ 12 mm for devices up to and including 11 kW
M6 x ≥ 16 mm for devices up to and including 22 kW
M8 x ≥ 16 mm for devices up to and including 110 kW