Connecon of one c
able technology (OCT) via HIPERFACE DSL®
Precondions
The One Cable Technology is only available in the devices < 22 kW.
The One Cable Technology (OCT) is possible with MCS and m850 servo motors.
The motor must be provided with a HIPERFACE DSL® encoder.
Connecon cable
-
The EYP008xxxxxxM11A00 or EYP008xxxxxxM12A00 hybrid cable must be used.
-
Dierent lengths up to 100 m are available. 4System cables ^ 171
The hybrid cables have only basic insulaon t
o the power electronics.
Preparaon of the cable
a
c
b
U
V
W
PE
T1
T2
BD1
BD2
1
0
23
bk 1
bk 2
bk 3
bk 5
gnye
bk 6
wh
bl
Fig. 12: Cable assembly
A Hybrid cable
B
Shield
C Conducve foil
D Heat-shrinkable tube
Inverter I75AE
211F1 222F1 240F1 275F1 311F1 315F1
211F2 222F2 240F2 275F2
Rated power P
r
ated
kW 1.1 2.2 4 7.5 11 15
Rated power P
rated
HP 1.5 3 5 10 15 20
Stripping length a mm 130 130
b mm 180 180
c mm 25 30
Electrical ins
tallaon
Connecon of one cable technology (OCT) via HIPERFACE DSL®
69