EasyManua.ls Logo

Lenze i750 - Safe Stop Emergency (SSE)

Lenze i750
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safe stop emergency (SSE)
The safety funcon SSE has the highes
t priority. The safety funcon SSE is controlled primarily
from all states, operang modes or safety funcons. Depending on the parameter seng in
0x28A3:001, SSE acvates one of these funcons:
4Safe torque o (STO)
4Sa
fe stop 1 (SS1)
Connect the emergency stop buon, which mus
t not be overridden by the safe
repair mode (RMS), to the SSE funcon via the safety controller and the safety
bus.
Funconal descripon
The SSE safety funcon iniates the parameterized stop funcon with the highest priority.
SSE
n
t
0
SS1
SSE
n
t
0
STO
STO
Fig. 15: Safety funcon SSE
Excepon
If a parameterized trigger source for SSE can be deacv
ated by the "Safe Mung" funcon,
SSE is not eecve during "Safe Mung".
Acvaon of the funcon
Via the sa
fety bus. 4Safe network interfaces ^ 149
Funconal sa
fety
Safety funcons
Safe stop emergency (SSE)
120

Table of Contents

Related product manuals