Compliance with EMC category C2 (r
esidenal areas)
Applicaons for the "rst environment" in residenal areas must comply with EMC category
C2.
DC bus connecon with one supplier or suppliers connected in parallel
Precondions
•
Max. motor cable length per inverter: 50 m.
•
The maximum sum of all motor cable lengths ∑ l
mot
must be observed:
When oper
ang with RFI lter without mains choke: Compliance with EMC
category C3 only for switching frequencies 4 kHz and 8 kHz.
∑ l
mot
f
or compliance with EMC category C2:
∑ I
mot
[m]
C2-2
n
20
18
16
14
12
10
8
6
4
2
50 100 150 200 250 300 400 500350 450
C2-1
Fig. 7: Max. sum of all motor cable lengths for compliance with EMC category C2
n Number of inverters
C2-1
Max. Sum of all motor cable lengths
with RFI lter E94AZRPxxxx
C2-2 Max. Sum of all motor cable lengths
with mains lter E94AZMPxxxx
Informaon on pr
oject planning
DC-bus connecon
Compliance with EMC category C2 (residenal areas)
41