Acvaon of the funcon
How to acv
ate Safe Mung:
1.»EASY Starter«:Open the +Safety parameter list+ tab.
»PLC Designer«:Open the Safe parameter set object under the axis in the device tree.
2.Click mung dialog.
The password dialog opens.
3.Enter mung password.
The mung dialog opens.
4.Use the displayed data to ensure that the correct inverter has been selected.
Opcal device idencaon is acvated automacally. The two LEDs "RDY" and "ERR" on
the front of the selected inverter ash quickly.
5.Start acvates the funcon.
The funcon is now acve for a maximum of 30 minutes.
The remaining me is displa
yed in 0x213B:002
6.End funcon
a)
The funcon is automacally ended aer 30 minutes.
b) Stop ends the funcon manually.
Monitored operaon is reacvated immediately.
All previously deacvated safety funcons are acve again.
Behavior of the funcon in the event of an error
If the Safe Mung funcon is aborted by an error, the monitored operaon is immediately
reacvated.
All previously deacvated safety funcons are acve again.
Reset mung password
The mung password can be reset in the LSPE: 0x213B:001 (MUT:Password) = 0.