Acvaon of the funcon
How to acv
ate Safe Mung:
1.»EASY Starter«:Open the +Safety parameter list+ tab.
»PLC Designer«:Open the Safe parameter set object under the axis in the device tree.
2.Click mung dialog.
The password dialog opens.
3.Enter mung password.
The mung dialog opens.
4.Use the displayed data to ensure that the correct inverter has been selected.
Opcal device idencaon is acvated automacally. The two LEDs "RDY" and "ERR" on
the front of the selected inverter ash quickly.
5.Start acvates the funcon.
The funcon is now acve for a maximum of 30 minutes.
The remaining me is displa
yed in 0x213B:002
6.End funcon
a)
The funcon is automacally ended aer 30 minutes.
b) Stop ends the funcon manually.
Monitored operaon is reacvated immediately.
All previously deacvated safety funcons are acve again.
Behavior of the funcon in the event of an error
If the Safe Mung funcon is aborted by an error, the monitored operaon is immediately
reacvated.
All previously deacvated safety funcons are acve again.
Reset mung password
The mung password can be reset in the LSPE: 0x213B:001 (MUT:Password) = 0.
Funconal sa
fety
Safety funcons
Safe Mung (MUT)
148