EasyManua.ls Logo

Lenze i750 - Page 93

Lenze i750
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Axis i750-C11/400-3 i750-C15/400-3
Rated power P
r
ated
kW 11 15
Rated power P
rated
hp 15 20
DC- Eingangsspannungsbereich DC 590 V ... 750 V
DC- Eingangsbemessungsstrom
without mains choke A 44.5 59.1
with mains choke A 29.7 39.4
DC-
Eingangsbemessungsleistung
without mains choke kW 18.3 24.3
with mains choke kW 18.3 24.3
Output voltage V 3 AC 0 - 480
Apparent output power kVA 18 23.9
Rated output current
4 kHz A 24 32
8 kHz A 19.2 25.6
16 kHz A 11.52 15.36
Power loss
4 kHz W 300 390
8 kHz W 260 340
16 kHz W 290 380
Overcurrent cycle 180 s
Max. output current A 36 48
Overload me T
1
s 60 60
Recovery me T
2
s 120 120
Max. output current during the
r
ecovery me
A 14.4 19.2
Overcurrent cycle 15 s
Max. output current A 48 64
Overload me T
1
s 3 3
Recovery me T
2
s 12 12
Max. output current during the
r
ecovery me
A 14.4 19.2
Max. shielded motor cable
length
without EMC category m 50
Kategorie C1 (4 kHz, 8 kHz,16
kHz)
m -
Kategorie C2 (4 kHz, 8 kHz,16
kHz)
m -
Kategorie C3 (4 kHz, 8 kHz,16
kHz)
m -
Max. Unshielded motor cable
length
without EMC category m 100
Technical data
3-phase mains c
onnecon 480 V
Axes data
93