Error and Notification Messages
www.lsi.com/channel/products 245
Action
If you see this message, the drive repairs may lie outside of the 3ware RAID
controllers abilities.Try running the drive manufacturers diagnostic and
repair utilities on the drive.
If necessary, replace the drive.
See Also
For links to drive manufacturer diagnostic utilities and troubleshooting
advice, search the LSI KnowledgeBase for keyword 10894 at
http://kb.lsi.com..
000B Rebuild started
Event Type
Information
Cause
The 3ware RAID controller started to rebuild a degraded unit. The rebuild
may have been initiated by you, may have started automatically on a hot spare
or may have started after drive removal or insertion (due to the Auto-Rebuild
policy).
Action
Allow the rebuild to complete. This will return the unit to its normal
redundant state.
See Also
“Scheduling Background Tasks” on page 163
“Rebuilding Units” on page 154
“Background Task Prioritization” on page 163
000C Initialize started
Event Type
Information
Cause
The 3ware RAID controller started an initialization. This is always a
“synching” background initialization and does not erase user data.
Initialization either occurs at unit creation time for larger RAID 5, 6, or 50
units or later during the initial verification of redundant units.

Table of Contents

Other manuals for LSI 3ware 9750

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSI 3ware 9750 and is the answer not in the manual?

LSI 3ware 9750 Specifications

General IconGeneral
BrandLSI
Model3ware 9750
CategoryController
LanguageEnglish

Related product manuals