Chapter 12. Troubleshooting
246 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2
Action
Allow the initialization to complete. This will return the unit to its normal
redundant state.
See Also
For more information, see “About Initialization” on page 146
000E Initialize failed
Event Type
Error
Cause
The 3ware RAID controller was unable to complete the initialization. This
error can be caused by unrecoverable drive errors.
If this unit was a redundant unit, and the initialization failed because of a
problem on a particular disk drive, then the unit will be degraded.
Action
If the unit was degraded, then rebuild the unit. This may necessitate replacing
the drive.
Check physical cable and power connections. You can also run the drive
manufacturer’s diagnostic and repair utilities on the drive.
See Also
For links to drive manufacturer diagnostic utilities and troubleshooting
advice, search the LSI KnowledgeBase for keyword 10894 at
http://kb.lsi.com.
“Basic Troubleshooting: Check This First” on page 228
000F SMART threshold exceeded
Event Type
Warning
Cause
SMART monitoring is predicting a potential drive failure.