EasyManua.ls Logo

LSI 3ware 9750 - Page 271

LSI 3ware 9750
380 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Error and Notification Messages
www.lsi.com/channel/products 259
0032 Spare capacity too small
Event Type
Warning
Cause
There is a valid hot spare but the capacity is not sufficient to use it for a drive
replacement in existing units.
Action
Replace the spare with a drive of equal or larger capacity than the existing
drives.
0033 Migration started
Event Type
Information
Cause
The 3ware RAID controller has started the migration of a unit.
Migration changes can include:
Expanding capacity of a unit by adding drives
Changing RAID levels, for example, from RAID 1 to RAID 5
See Also
“RAID Level Migration (RLM) Overview” on page 116
0034 Migration failed
Event Type
Error
Cause
The migration of a unit has failed.
Migration changes can include:
Expanding capacity of a unit by adding drives.
Changing RAID levels, for example, from RAID 1 to RAID 5

Table of Contents

Other manuals for LSI 3ware 9750

Related product manuals