Chapter 12. Troubleshooting
260 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2
Action
Review the list of events on the Alarms page for other entries that may give
you an idea of why the migration failed (for example, a drive error on a
specific port).
You may also wish to get the logs and contact technical support at
http://www.lsi.com/channel/ContactUs. For information on collecting logs,
search the LSI KnowledgeBase for keyword 12278 at http://kb.lsi.com..
See Also
“RAID Level Migration (RLM) Overview” on page 116
0035 Migration completed
Event Type
Information
Cause
The migrated unit is now ready to be used.
Migration changes can include:
• Expanding capacity of a unit by adding drives
• Changing RAID levels, for example, from RAID 1 to RAID 5.
Action
If the capacity of the unit did not change, then you do not need to do anything
else. If the capacity of the migrated unit is larger, you will need to inform the
operating system of the change. See “Informing the Operating System of
Changed Configuration” on page 119.
0036 Verify fixed data/parity mismatch
Event Type
Warning
Cause
A verify error was found and fixed by the 3ware RAID controller.
Some examples of errors that can be fixed include: