Error and Notification Messages
www.lsi.com/channel/products 263
003B Rebuild paused
Event Type
Information
Cause
The rebuild operation is paused.
Rebuilds are normally paused for two (formerly ten) minutes after a system
first boots up and during non-scheduled times when scheduling is enabled.
Disabling or modifying the schedule with 3DM2 or CLI will allow the rebuild
to resume.
See Also
“Scheduling Background Tasks” on page 163
003C Initialize paused
Event Type
Information
Cause
The initialization is paused.
Initializations are normally paused for two (formerly ten) minutes after a
system first boots up. Initialization is also paused during non-scheduled times
when scheduling is enabled. Initializations follow the rebuild schedule.
Action
If you want the initialize to resume, you can disable or modify the schedule
through 3DM2 or CLI.
See Also
“Viewing Current Task Schedules” on page 165
“About Initialization” on page 146