©Copyright MAC Instruments 2005. All Rights Reserved. MAC155 Rev. 12
Pg 5
PROBE OPTIONS
There are several options available with the MAC155 Probe. Each option is
explained in detail in the following sections.
EXTENSION TUBE
The optional extension tube is 3 foot/0.9 meter in length and can be affixed to
the end of the MAC155 Probe using standard tube fittings. The purpose of the
extension tube is to draw the sample atmosphere at a point well away from the
wall of the stack or duct. The 3 foot/0.9 meter extension tube can be cut to any
desired length.
Figure 2 – Extension Tube cut to 12 inch/ 30cm
CASE HEATER
The MAC155 Probe contains water that must be protected from freezing
when the instrument is mounted outside in geographic locations where the
ambient temperature may fall below 32°F / 0°C. The case heater option will
protect the unit from freezing to temperatures as low as -40°F / -40°C. The case
heater will draw a maximum of 1 amp.