IMPULSE•G+ Mini Advanced Instruction Manual – March 2014
5-74
Parameter
Code Name Function Range
Initial
Value
Access
Level
L06.05 Torque Detection 2 Level Torque Detection 2 Level 0–300% 150 Adv
L06.06 Torque Detection 2 Time Torque Detection 2 Time 0.0–10.0 sec 0.1 Adv
L06.08 Mechanical Weakening
Detection Selection
Determines the action to take
during and after detection
00–08 00 Adv
00 Disabled
01 Speed (signed) >
L06.09; Continue
Running (Alarm)
02 Speed (unsigned) >
L06.09; Continue
Running (Alarm)
03 Speed (signed) >
L06.09; Stop
(Protection)
04 Speed (unsigned) >
L06.09; Stop
(Protection)
05 Speed (signed) <
L06.09; Continue
Running (Alarm)
06 Speed (unsigned) <
L06.09; Continue
Running (Alarm)
07 Speed (signed) <
L06.09; Stop
(Protection)
08 Speed (unsigned) <
L06.09; Stop
(Protection)
L06.09 Mechanical Weakening
Detection Speed Level
Sets the speed for Load
Weakening Detection
-110.0–100.0% 100.0 Adv
L06.10 Mechanical Weakening
Detection Time
Sets the time required for
Mechanical Weakening to be
detected before triggering
parameter L06.08.
0.0–10.0 sec 0.1 Adv
L06.11 Mechanical Weakening
Detection Start Time
Mechanical Weakening
Detection is triggered when the
cumulative operation time
exceeds U04.01.
00000–65535 00000 Adv