IMPULSE•G+ Mini Advanced Instruction Manual – March 2014
5-86
Clear History
63 2A0006 2005-G+M
64 -- Not used
65 2A0010 2008-G+M
66 2A0012 2011-G+M
67 2A0018 Not used
68 2A0020 2017-G+M
69 -- Not used
6A 2A0030 2025-G+M
6B 2A0040 2033-G+M
6C -- Not used
6D 2A0056 2047-G+M
6E 2A0069 2060-G+M
91 4A0001 4001-G+M
92 4A0002 4002-G+M
93 4A0004 4003-G+M
94 4A0005 4004-G+M
95 4A0007 4005-G+MF (OEM only)
96 4A0009 4007-G+MF (OEM only)
97 4A0011 4009-G+M
98 -- Not used
99 4A0018 4014-G+M
9A 4A0023 4018-G+M
9B -- Not used
9C 4A0031 4024-G+M
9D 4A0038 4031-G+M
O02.05 Operator M.O.P. Selects whether the ENTER key is
used when the frequency reference is
set by the digital operator. The digital
operator can simulate a motor
operated potentiometer (M.O.P.) by
setting this parameter.
00, 01 00 Adv
00 Disabled ENTER Key Required Note: This feature cannot be used in
conjunction with infinitely variable
speed control.
01 Enabled ENTER Key Not Required
O02.07 Motor Direction at Power-
Up
Sets direction of motor at power-up. 00, 01 00 Adv
00 Forward
01 Reverse
Parameter
Code Name Function Range
Initial
Value
Access
Level
Parameter
Code Name Function Range
Initial
Value
Access
Level
O03.01 Elapsed Time Setting -- 0000–9999hr 0000 Adv