Acceleration/Deceleration
Acceleration time sets the time necessary for the output frequency to accelerate from 0Hz to
maximum output frequency (E01.04). Deceleration time sets the time necessary for the output
frequency to decelerate from the maximum output frequency (E01.04) to 0Hz.
Parameter
Code Name Function Range Initial Value
Access
Level
B05.01 Accel Time 1 Sets acceleration time. 0.0–25.5 sec 5.0* Basic/Adv
B05.02 Decel Time 1 Sets deceleration time. 0.0–25.5 sec 3.0* Basic/Adv
B05.03 Accel Time 2 Sets alternate accel time.
Enabled by multi-function input=1A.
0.0–6000.0 sec 2.0 Basic/Adv
B05.04 Decel Time 2 Sets alternate decel time.
Enabled by multi-function input=1A.
0.0–6000.0 sec 2.0 Basic/Adv
B05.05 Accel Time N Change Sets acceleration time at Speed Switch
frequency.
0.0–25.5 sec 2.0 Adv
B05.06 Decel Time N Change Sets deceleration time at Speed
Switch frequency.
0.0–25.5 sec 2.0 Adv
B05.08 Fault Stop Time Sets deceleration time for complete
stop at external fault. See External
Response Selection page 5-51.
0.0–25.5 sec 1.0 Adv
B05.09 Accel/Decel Units Determines acceleration/deceleration
switching level
00, 01 01 Adv
00 0.01 sec for 0.00-
2.55 sec
NOTE: Setting will not change if
any accel/decel time is >
2.55 sec.
01 0.1 sec for 0.0-25.5
sec
B05.10 Accel/Decel Switch
Frequency
Determines acceleration/deceleration
switching level
0.0–150.0 Hz 120 Adv
B05.11 Switch Frequency Determines when Acceleration Time
and Deceleration Time at Speed
Switch Hz is enabled
0.0–6000.0 01 Adv
00 lower SW freq B05.05/06 is enabled, N-out B5.10
01 upper SW freq B05.06 is enabled, N-out B5.10
B05.12 Accel Time 3 Acceleration time when H01.01 to
H01.07 = 1B
0.0–6000.0 3.0 Adv
B05.13 Decel Time 3 Deceleration time when H01.01 to
H01.07 = 1B
0.0–6000.0 3.0 Adv
B05.14 Accel Time 4 Acceleration time when H01.01 to
H01.07 = 1C
0.0–6000.0 3.0 Adv
B05.15 Decel Time 4 Deceleration time when H01.01 to
H01.07 = 1C
0.0–6000.0 3.0 Adv
* Initial value is determined by X-Press Programming (Table 4.1 to 4.2).