IMPULSE•G+ Mini Advanced Instruction Manual – March 2014
4-13
Initialization Set-up
Parameter Access Level (A01.01)
This parameter controls the level of access for all the parameters in the drive. Using this parameter
controls the “masking” of parameters according to the access level selected. There are three access
levels available - BASIC, ADVANCED and USER. When the access level is set to ADVANCED
(A01.01 = 0002), it will allow access to all parameters outlined in this manual.
Changing the access level to USER (A01.01 = 0000) limits access to only parameters stored in the
A02.xx table (up to 32). To set up the A02.xx group, refer to page 4-14.
Control Method Selection (A01.02)
Select the control method best suited for your application.
NOTE: An auto-tune must be performed for all open loop vector applications. Refer to the Auto-
Tuning section on page 4-15.
Setting Description
0000 User Program - Allows read/write capabilities for parameters selected by OEM
(A02.01 to A02.32).
0001 Basic Level - Access to parameters for general crane applications.
0002 Advanced Level - for advanced programming in special applications.
Setting Description Access Level
00 V/f Control—For general purpose and multiple motor applications. Basic/Adv
02 OLV—Open Loop Vector; for applications requiring precise speed control,
quick response and higher torque at low speeds (150% torque below 1 Hz).
Adv