Terminal Parameters
There are both digital and analog inputs and outputs that can be programmed for customized
operation and sequencing. These include input and output terminal selection along with serial
communication. Listed below are the parameters in this section that are customizable for your
system.
• H1 Digital Inputs
• H2 Digital Outputs
• H3 Analog Inputs
• H4 Analog Outputs
• H5 Serial Communication Set-up
• H6 Pulse Inputs
Digital Inputs
The IMPULSE•G+ Mini has seven multi-function contact inputs for the set-up of numerous
functions. The following table lists the function selections for the multi-function contact inputs
(terminals S1 to S7) and indicates the control modes during which each function can be enabled. An
OPE03 error will occur if the same function is programmed in more than one terminal at the same
time.
Parameter
Code Name Function
Reference
Page
Number Range
Initial
Value
Access
Level
H01.01 Terminal S1 Select Selects the multi-function
inputs. Setting for S1.
-- 00–81 80* Basic/Adv
H01.02 Terminal S2 Select Setting for S2. -- 00–81 81* Basic/Adv
H01.03 Terminal S3 Select Setting for S3. -- 00–81 00* Basic/Adv
H01.04 Terminal S4 Select Setting for S4. -- 00–81 01* Basic/Adv
H01.05 Terminal S5 Select Setting for S5. -- 00–81 0F* Basic/Adv
H01.06 Terminal S6 Select Setting for S6. -- 00–81 0F* Basic/Adv
H01.07 Terminal S7 Select Setting for S7. -- 00–81 0F* Basic/Adv
00 Multi-Step Ref 2 Multi-Step Speed 2. 5-3 Basic/Adv
01 Multi-Step Ref 3 Multi-Step Speed 3. 5-3 Basic/Adv
02 Multi-Step Ref 4 Multi-Step Speed 4. 5-3 Basic/Adv
03 Multi-Step Ref 5 Multi-Step Speed 5. 5-3 Basic/Adv
04 Speed Hold 2 Hold function (2nd step of
Three-Step Infinitely Variable).
-- Basic/Adv
05 Accel Command Acceleration function (2nd step
of Two-Step Infinitely Variable
or 3rd step of Three-Step
Infinitely Variable).
5-3 Basic/Adv
06 Upper Limit 1 N.O. Upper Limit - SLOW DOWN;
Normally Open. UL1 - blinking
5-20 Basic/Adv
07 Upper Limit 2 N.O. Upper Limit - STOP; Normally
Open. UL2 - blinking
5-20 Basic/Adv
08 Lower Limit 1 N.O. Lower Limit - SLOW DOWN;
Normally Open. LL1 - blinking
5-20 Basic/Adv