IMPULSE•G+ Mini Advanced Instruction Manual – March 2014
5-87
O03.02 Elapsed Time Selection Selects how the Elapsed Time is
accumulated
00, 01 01 Adv
00 Power On Time
01 Running Time
O03.03 Fan On Time -- 0000–9999hr 0000 Adv
O03.05 Capacitor Maintenance
Time
-- 000–150% 000 Adv
O03.07 Inrush Preventative
Maintenance Relay Setting
-- 000–150% 000 Adv
O03.09 IGBT Maintenance Setting -- 000–150% 000 Adv
O03.11 Fault Trace Clear Clears Fault History 00, 01 00 Adv
00 Not Cleared
01 Clear U2/U3
O03.12 kWh Monitor Initial Value
Selection
Sets kWh Monitor Initial Value 00, 01 00 Adv
00 Save
01 Reset
O03.14 Clear Count History Clears count history 00–03 00 Adv
00 Not Clear
01 Clear AC Count
02 Clear OL/LC Count
03 Clear Both Counts
Parameter
Code Name Function Range
Initial
Value
Access
Level

Table of Contents

Other manuals for Magnetek 2001-G+M