IMPULSE•G+ Mini Advanced Instruction Manual – March 2014
5-76
L08.18 Soft CLA Sel Enables/disables the software current
limit function. Limits output
frequency when current exceeds
110% of rated.
00–01 01 Adv
00 Disabled
01 Enabled
L08.19 Overheat Pre-Alarm
Frequency Reduction Rate
0.1–0.9% 0.8 Adv
L08.35 Mounting Selection Mounting selection 00–03 00 Adv
00 Disabled (Standard
Installation)
01 Side-by-Side
02 NEMA 1 Standard
03 Finless
L08.41 High Current Alarm
Selection
High current alarm selection 00–01 00 Adv
00 Disable
01 Enable
Parameter
Code Name Function Range
Initial
Value
Access
Level