IMPULSE•G+ Mini Advanced Instruction Manual – March 2014
5-78
Example:
Enable auto-reset for UV2 and CE faults.
1. Place a “1” above UV2 and CE faults.
2. Convert binary to hexadecimal using Table 5-16 for each digit.
3. Program L09.04 to 0003 to enable UV2 and UV1 from Table 5-12.
4. Program L09.05 to E080 to enable BE1, BE2, CoF, and CE from Table 5-16.
Table 5-12: Auto Reset Table (default)
Digit 4 Digit 3 Digit 2 Digit 1
HEX 0 0 0 1
Binary 0000000000000001
L09.04 E
F
0
-
-
-
-
-
-
-
-
-
L
F
P
F
U
T
1
-
-
-
O
H
1
S
C
O
V
G
F
O
C
U
V
3
U
V
2
U
V
1
HEX E 0 0 0
Binary 1110000000000000
L09.05 B
E
1
B
E
2
C
O
F
F
B
L
O
L
1
O
L
2
O
T
1
O
T
2
C
E
C
A
L
L
-
-
-
E
F
7
E
F
6
E
F
5
E
F
4
E
F
3
Table 5-13: Auto Reset Table with UV2 and CE Fault (modified)
Digit 4 Digit 3 Digit 2 Digit 1
HEX 0 0 0 3
Binary 0000000000000011
L09.04 E
F
0
-
-
-
-
-
-
-
-
-
L
F
P
F
U
T
1
-
-
-
O
H
1
S
C
O
V
G
F
O
C
U
V
3
U
V
2
U
V
1
HEX E 0 8 0
Binary 1110000010000000
L09.05 B
E
1
B
E
2
C
O
F
F
B
L
O
L
1
O
L
2
O
T
1
O
T
2
C
E
C
A
L
L
-
-
-
E
F
7
E
F
6
E
F
5
E
F
4
E
F
3