IMPULSE•G+ Mini Advanced Instruction Manual – March 2014
5-89
U01.12 Inverter Control Status Operation Status -- Basic/Adv
U01.13 Elapsed Time Cumulative operation time at drive. Defined by O03.02. hours Basic/Adv
U01.14 Flash ID Flash ROM software ID number -- Basic/Adv
U01.15 Terminal A1 Level External Terminal input level V Basic/Adv
U01.16 Terminal A2 Level External Terminal input level V/mA Basic/Adv
U01.20 Output Frequency after
Soft Start
--- Hz Adv
U01.28 Software CPU --- -- Adv
U01.34 OPE Detection Parameter Parameter OPE detected const # Basic/Adv
U01.39 Memobus
Communication Error
Displays content of MEMOBUS error -- Adv
U01.52 Maintenance Timer hr Adv
U01.54 Pulse Monitor Displays the pulse train input RP frequency -- Adv
U01.64 LC Zone Displays the LC Zone the drive is currently running in. If
an LC Fault occurs, the value displayed will be which LC
Zone the LC Fault occurred.
-- Adv
U01.65 LC Margin Displays how close the current/torque levels are to the
target value for each of the LC Zones. Values less than
zero will cause an LC Detection and/or LC Fault to occur.
If the LC Fault occurs, the value displayed will be the
amount the level was below the LC Zone setting.
%Adv
Parameter
Code Name Function Units
Access
Level