REMOVE THE TUB
Remove entire cabinet (see page 4-17).
Remove the agitator (see page 4-23).
Remove the tub ring (see page 4-24).
Remove the basket (see page 4-27).
Remove the spring, which counterbalances
the motor hanging on the front of the
washer.
1.
2.
3.
4.
5.
Spring
Clamp
Strap
Remove the tub hose clamp with a pair of
pliers and pull the hose off the tub outlet.
6.
Release the plastic strap that holds the
feature panel to the base by rotating the
strap and pulling the tab through the slot in
the feature panel. This will allow the feature
panel to lean back further.
7.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.