EasyManua.ls Logo

Maytag MAT14CS - Remove Inlet Valve

Maytag MAT14CS
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-46
REMOVE INLET VALVE
Remove the 5/16 inch hex head screw that
secures the inlet valve mounting plate to the
rear of the feature panel.
1.
5/16 inch
hex screw
1/4 inch screw
Mounting plate
Lift the mounting plate up and tilt away from
the feature panel to remove the mounting
plate, inlet valve, thermistor and gain
access to the inlet tubing connection.
Remove the 1/4 inch screw that secures it
to the mounting plate.
2.
3.
Slide the valve up to remove the valve from
the oblong holes that hold it tightly in the
mounting plate.
4.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.

Table of Contents

Related product manuals