Refilling antifreeze mixed water
4-35
4
Maintenance
Refilling antifreeze mixed water
If water lack error is displayed, refill antifreeze mixed water.
1
Uncover the feed-water inlet and the air vent.
2
Remove all remaining water in the tank.
(1) Remove all water in the tank with a provided syringe from
the feed-water inlet.
(2) Put the removed water into the tank with a cap, and
discard it.
3
Mix antifreeze liquid with water.
(1) Mix 1 part antifreeze liquid with 2 parts water.
(2) Put the mixed water into a provided syringe.
4
Refill antifreeze liquid.
Fill the antifreeze liquid from the feed-water inlet.
Put the liquid of 50ml into the syringe, and put it into the device.
Repeat this 9 times to fill up (450ml).
5
Cover the feed-water inlet and the air vent.
feed-water inlet
air vent cover