Various settings
3-29
3
Useful Function
Setting radiator pump (only for UJF-3042HG)
On UJF-3042 and UJF-3042FX, if the noise of the cooling pump for LED UV unit become louder after updating
the firmware to the version 3.10 or later, change the setting as follows. This setting change is applicable on the
firmware version 3.10 and later. On UJF-3042HG, this noise problem does not occur.
(Supported from the firmware ver.3.10)
1
Press the key in the local mode.
2
Press the [MACHINE SET] by pressing the or
key, and press the key.
3
Select the [RADIATOR PUMP] by pressing the
or key, and press the key.
4
The current pump type is displayed.
5
Select the [Type B] by pressing the or
key, and press the key.
6
Press the key several times to end the setting.