5 SYSTEM CONFIGURATION
5.5 Connection Examples
115
5
Servo amplifier (CC-Link IE TSN Class B) connection
The following figure shows connection of master/local module + servo amplifiers (CC-Link IE TSN Class B).
To build this configuration, use the master station (FX5-CCLGN-MS) with a firmware version of "1.020" or
later.
When the firmware version of the master station (FX5-CCLGN-MS) is "1.010" or earlier, the servo amplifiers
cannot be connected.
No.0: FX5-CCLGN-MS (master station)
No.1, No.2: RJ71GN11-T2 (local station)
No.3: FX5-CCLGN-MS (local station)
No.4, No.5, and No.6: Servo amplifier
No.0
Class B (1Gbps)
No.1
Class B (1Gbps)
No.2
Class B (1Gbps)
No.3
Class B (1Gbps)
No.4
Class B(1Gbps)
No.5
Class B(1Gbps)
No.6
Class B(1Gbps)