1010
APPENDICES
Appendix 1 Operation Processing Time
Application
instruction
LEN 1 character 1.200 3.400 1.200 3.400 1.200 3.400
96 characters 8.900 11.100 8.900 11.100 8.900 11.100
STR 2.600 11.600 2.600 11.600 2.600 11.600
DSTR 2.900 11.600 2.900 11.600 2.900 11.600
VAL 3.700 14.100 3.700 14.100 3.700 14.100
DVAL 4.400 160.000 4.400 160.000 4.400 160.000
ESTR 4.200 23.700 4.200 23.700 4.200 23.700
LDTM= Comparison of
specified clock
In conductive
status
2.600 14.700 2.600 14.700 2.600 14.700
In non-
conductive status
2.600 14.300 2.600 14.300 2.600 14.300
Comparison of current
clock
In conductive
status
4.900 21.600 4.900 21.600 4.900 21.600
In non-
conductive status
4.800 22.500 4.800 22.500 4.800 22.500
ANDTM= When not executed 0.018 0.018 0.018
Comparison of
specified clock
In conductive
status
2.500 14.400 2.500 14.400 2.500 14.400
In non-
conductive status
2.600 14.100 2.600 14.100 2.600 14.100
Comparison of current
clock
In conductive
status
4.700 21.600 4.700 21.600 4.700 21.600
In non-
conductive status
4.800 22.200 4.800 22.200 4.800 22.200
ORTM= When not executed 0.018 0.018 0.018
Comparison of
specified clock
In conductive
status
2.600 14.800 2.600 14.800 2.600 14.800
In non-
conductive status
2.600 14.300 2.600 14.300 2.600 14.300
Comparison of current
clock
In conductive
status
4.900 21.900 4.900 21.900 4.900 21.900
In non-
conductive status
4.700 22.000 4.700 22.000 4.700 22.000
LDTM<> Comparison of
specified clock
In conductive
status
2.600 14.400 2.600 14.400 2.600 14.400
In non-
conductive status
2.600 14.700 2.600 14.700 2.600 14.700
Comparison of current
clock
In conductive
status
4.800 22.300 4.800 22.300 4.800 22.300
In non-
conductive status
4.800 21.800 4.800 21.800 4.800 21.800
ANDTM<> When not executed 0.018 0.018 0.018
Comparison of
specified clock
In conductive
status
2.600 14.200 2.600 14.200 2.600 14.200
In non-
conductive status
2.600 14.600 2.600 14.600 2.600 14.600
Comparison of current
clock
In conductive
status
4.600 22.200 4.600 22.200 4.600 22.200
In non-
conductive status
4.800 21.600 4.800 21.600 4.800 21.600
Category Instruction Condition (device) Processing time (s)
Q03UDVCPU Q04UDVCPU Q06UDVCPU,
Q13UDVCPU,
Q26UDVCPU
Min. Max. Min. Max. Min. Max.