APPENDICES
Appendix 1 Operation Processing Time
1011
A
Application
instruction
ORTM<> When not executed 0.018 0.018 0.018
Comparison of
specified clock
In conductive
status
2.600 15.000 2.600 15.000 2.600 15.000
In non-
conductive status
2.600 14.900 2.600 14.900 2.600 14.900
Comparison of current
clock
In conductive
status
4.800 22.300 4.800 22.300 4.800 22.300
In non-
conductive status
4.700 21.500 4.700 21.500 4.700 21.500
LDTM> Comparison of
specified clock
In conductive
status
2.600 14.300 2.600 14.300 2.600 14.300
In non-
conductive status
2.600 14.300 2.600 14.300 2.600 14.300
Comparison of current
clock
In conductive
status
4.800 22.400 4.800 22.400 4.800 22.400
In non-
conductive status
4.800 21.700 4.800 21.700 4.800 21.700
ANDTM> When not executed 0.018 0.018 0.018
Comparison of
specified clock
In conductive
status
2.500 14.500 2.500 14.500 2.500 14.500
In non-
conductive status
2.600 14.900 2.600 14.900 2.600 14.900
Comparison of current
clock
In conductive
status
4.600 22.000 4.600 22.000 4.600 22.000
In non-
conductive status
4.800 21.800 4.800 21.800 4.800 21.800
ORTM> When not executed 0.018 0.018 0.018
Comparison of
specified clock
In conductive
status
2.600 14.400 2.600 14.400 2.600 14.400
In non-
conductive status
2.500 14.400 2.500 14.400 2.500 14.400
Comparison of current
clock
In conductive
status
4.800 22.700 4.800 22.700 4.800 22.700
In non-
conductive status
4.700 21.800 4.700 21.800 4.700 21.800
LDTM<= Comparison of
specified clock
In conductive
status
2.600 14.400 2.600 14.400 2.600 14.400
In non-
conductive status
2.600 14.400 2.600 14.400 2.600 14.400
Comparison of current
clock
In conductive
status
4.800 22.200 4.800 22.200 4.800 22.200
In non-
conductive status
4.800 22.100 4.800 22.100 4.800 22.100
ANDTM<= When not executed 0.018 0.018 0.018
Comparison of
specified clock
In conductive
status
2.600 14.400 2.600 14.400 2.600 14.400
In non-
conductive status
2.600 14.500 2.600 14.500 2.600 14.500
Comparison of current
clock
In conductive
status
4.600 21.800 4.600 21.800 4.600 21.800
In non-
conductive status
4.700 22.400 4.700 22.400 4.700 22.400
Category Instruction Condition (device) Processing time (s)
Q03UDVCPU Q04UDVCPU Q06UDVCPU,
Q13UDVCPU,
Q26UDVCPU
Min. Max. Min. Max. Min. Max.

Table of Contents