1014
APPENDICES
Appendix 1 Operation Processing Time
Application
instruction
ANDDT<> When not executed 0.018 0.018 0.018
Comparison of
specified date
In conductive
status
2.600 15.100 2.600 15.100 2.600 15.100
In non-
conductive status
2.700 15.400 2.700 15.400 2.700 15.400
Comparison of current
date
In conductive
status
4.600 22.100 4.600 22.100 4.600 22.100
In non-
conductive status
4.700 22.500 4.700 22.500 4.700 22.500
ORDT<> When not executed 0.018 0.018 0.018
Comparison of
specified date
In conductive
status
2.700 15.100 2.700 15.100 2.700 15.100
In non-
conductive status
2.600 15.100 2.600 15.100 2.600 15.100
Comparison of current
date
In conductive
status
4.800 22.600 4.800 22.600 4.800 22.600
In non-
conductive status
4.700 22.800 4.700 22.800 4.700 22.800
LDDT> Comparison of
specified date
In conductive
status
2.700 14.700 2.700 14.700 2.700 14.700
In non-
conductive status
2.700 14.500 2.700 14.500 2.700 14.500
Comparison of current
date
In conductive
status
4.800 22.400 4.800 22.400 4.800 22.400
In non-
conductive status
4.800 21.800 4.800 21.800 4.800 21.800
ANDDT> When not executed 0.018 0.018 0.018
Comparison of
specified date
In conductive
status
2.600 15.000 2.600 15.000 2.600 15.000
In non-
conductive status
2.700 15.100 2.700 15.100 2.700 15.100
Comparison of current
date
In conductive
status
4.600 22.100 4.600 22.100 4.600 22.100
In non-
conductive status
4.500 22.000 4.500 22.000 4.500 22.000
ORDT> When not executed 0.018 0.018 0.018
Comparison of
specified date
In conductive
status
2.700 15.300 2.700 15.300 2.700 15.300
In non-
conductive status
2.600 15.000 2.600 15.000 2.600 15.000
Comparison of current
date
In conductive
status
4.800 21.500 4.800 21.500 4.800 21.500
In non-
conductive status
4.700 22.400 4.700 22.400 4.700 22.400
LDDT<= Comparison of
specified date
In conductive
status
2.700 14.500 2.700 14.500 2.700 14.500
In non-
conductive status
2.700 14.500 2.700 14.500 2.700 14.500
Comparison of current
date
In conductive
status
4.800 22.600 4.800 22.600 4.800 22.600
In non-
conductive status
4.800 22.600 4.800 22.600 4.800 22.600
Category Instruction Condition (device) Processing time (s)
Q03UDVCPU Q04UDVCPU Q06UDVCPU,
Q13UDVCPU,
Q26UDVCPU
Min. Max. Min. Max. Min. Max.