130
4 HOW TO READ INSTRUCTIONS
*1 For the description for the individual devices, refer to the User's Manual (Function Explanation, Program Fundamentals) for the CPU
module used.
*2 FX and FY can be used only for bit data, and FD only for word data.
*3 When T, ST, and C are used for other than the instructions below, only word data can be used. (Bit data cannot be used.)
[Instructions that can be used with bit data]
LD, LDI, AND, ANI, OR, ORI, LDP, LDF, ANDP, ANDF, ORP, ORF, LDPI, LDFI, ANDPI, ANDFI, ORPI, ORFI, OUT, RST, BKRST
*4 Usable with CC-Link IE Controller Network, CC-Link IE Field Network, MELSECNET/H, and MELSECNET/10.
*5 The "Constant" and "Other" columns describe the devices which can be set.
Indicates ladder mode expressions and execution conditions for instructions.
Execution condition Non-conditional
execution
Executed at ON Executed at the
rising edge
Executed at OFF Executed at the
falling edge
Code recorded on
description page
No symbol recorded
For execution conditions, refer to Page 117 Conditions for Execution of Instructions.
Indicates the data set for each instruction and the data type.
Data type Description
Bit Bit data or head number in bit data
BIN 16 bits BIN 16-bit data or head number in word device
BIN 32 bits BIN 32-bit data or head number in word device
BIN 64 bits BIN 64-bit data or head number in word device
BCD 4-digit 4-digit BCD data
BCD 8-digit 8-digit BCD data
Real number Floating decimal point data
Character string Character string data
Device name Device name data
Devices which can be used by the instruction in question are indicated with . The types of devices that can be used are as indicated below:
Setting
data
Internal device (system,
user)
File
register
R, ZR
Link direct device
J\
*4
Intelligent
function module
U\G
Index
register
Zn
Constant
*5
Others
*5
Bit Word Bit Word
Usable
devices
*1
X, Y, M, L,
SM, F, B,
SB, FX
*2
,
FY
*2
T
*3
, ST
*3
, C
*3
,
D, W, SD, SW,
FD
*2
, @
R, ZR J\X
J\Y
J\B
J\SB
J\W
J\SW
U\G Z K, H, E, $ P, I, J, U, DX,
DY, N, BL,
TR, BL\S, V
Indicates the function of the instruction.
Indicates conditions under which error is returned, and error number. See Page 110 Cautions on Programming (Operation Errors) for errors not included
here.
Indicates both ladder and list for simple program example. Also indicates the types of individual devices used when the program is executed.

Table of Contents

Related product manuals