7 APPLICATION INSTRUCTIONS
7.6 Structure Creation Instructions
469
7
If the FCALL (P) instruction is used in conjunction with the CALL(P) instruction, non-execution processing of a subroutine
program is performed when the execution command is turned OFF, enabling forcible turning OFF of the OUT instruction
and the PLS instruction (including P instructions). In case the FCALL (P) instruction is not used in conjunction with the
CALL(P) instruction, non-execution processing of a subroutine program is not performed even if the execution command is
turned OFF. Therefore, output status of the individual coil instructions remains unchanged.
X0
P0
X1
Y10
Y11
SET
M0PLS
RET
X0
X1
Y10
Y11
M0
X0
X1
Y10
Y11
M0
P0CALL
P0FCALL
FEND
X0
P0
X1
Y10
Y11
SET
M0PLS
RET
P0CALL
FEND
·
·
When FCALL instruction is not used
When FCALL instruction is used
Forced OFF by FCALL instruction