7 APPLICATION INSTRUCTIONS
7.18 PID Instruction
Operation of output value
•PID control
Auto tuning with maximum output 90%
ONONON
OFF
ON ON
<Cycle>
2 seconds (2000ms) 2 seconds (2000ms)
D502 × 1ms <On time>
2 seconds (2000ms)
2 seconds (2000ms) 2 seconds (2000ms)2 seconds (2000ms)
1.8 seconds (1800ms) 1.8 seconds (1800ms) 1.8 seconds (1800ms)