EasyManua.ls Logo

Mitsubishi Electric MELSEC-Q/L - Page 948

Mitsubishi Electric MELSEC-Q/L
1084 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
946
APPENDICES
Appendix 1 Operation Processing Time
Table of the time to be added when F/T(ST)/C device is used in OUT/SET/RST instruction
When using Q00UJCPU, Q00UCPU, Q01UCPU and Q02UCPU
When using Q03UD(E)HCPU, Q04UD(E)HCPU, Q06UD(E)HCPU, Q10UD(E)HCPU, Q13UD(E)HCPU, Q20UD(E)HCPU,
Q26UD(E)HCPU, Q50UDEHCPU, and Q100UDEHCPU
Instruction
name
Device
name
Condition Addition time (s)
Q00UJCPU Q00UCPU Q01UCPU Q02UCPU
OUT F When not executed 2.900 2.900 2.900 2.100
When executed 116.000 116.000 116.000 68.800
T(ST), C When not executed 0.360 0.240 0.180 0.120
When
executed
After time up 0.360 0.240 0.180 0.120
When added 0.360 0.240 0.180 0.120
SET F When not executed 0.120 0.080 0.006 0.004
When executed 116.000 116.000 116.000 68.600
RST F When not executed 0.120 0.080 0.006 0.004
When executed 55.800 55.800 55.800 26.500
T(ST), C When not executed 0.360 0.240 0.180 0.120
When executed 0.360 0.240 0.180 0.120
Instruction
name
Device
name
Condition Addition time (s)
Q03UD(E)CPU Q04UD(E)HCPU,
Q06UD(E)HCPU
Q10UD(E)HCPU,
Q13UD(E)HCPU,
Q20UD(E)HCPU,
Q26UD(E)HCPU
Q50UDEHCPU,
Q100UDEHCPU
OUT F When not executed 1.940 1.570 1.570 1.570
When executed 39.930 38.090 38.090 38.090
T(ST), C When not executed 0.060 0.030 0.030 0.030
When executed After time up 0.060 0.030 0.030 0.030
SET F When not executed 0.000 0.000 0.000 0.000
When executed 42.900 40.600 40.600 40.600
RST F When not executed 0.000 0.000 0.000 0.000
When executed 45.260 36.600 36.600 36.600
T(ST), C When not executed 0.060 0.030 0.030 0.030
When executed 0.060 0.030 0.030 0.030

Table of Contents