APPENDICES
Appendix 1 Operation Processing Time
951
A
Basic
instruction
LDED> Double
precision
In conductive status 4.700 37.400 4.700 37.400 4.700 37.400 5.100 25.100
In non-conductive status 4.700 37.400 4.700 37.400 4.700 37.400 4.200 23.400
ANDED> Double
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.500 34.700 4.500 34.700 4.500 34.700 4.000 19.500
In non-
conductive
status
4.500 34.700 4.500 34.700 4.500 34.700 4.100 19.700
ORED> Double
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.700 33.200 4.700 33.200 4.700 33.200 5.000 24.200
In non-
conductive
status
4.700 33.200 4.700 33.200 4.700 33.200 4.900 25.800
LDED<= Double
precision
In conductive status 4.700 37.400 4.700 37.400 4.700 37.400 4.200 22.500
In non-conductive status 4.700 37.400 4.700 37.400 4.700 37.400 4.200 13.500
ANDED<= Double
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.500 34.700 4.500 34.700 4.500 34.700 4.000 19.600
In non-
conductive
status
4.500 34.700 4.500 34.700 4.500 34.700 4.100 19.700
ORED<= Double
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.700 33.200 4.700 33.200 4.700 33.200 5.000 26.300
In non-
conductive
status
4.700 33.200 4.700 33.200 4.700 33.200 5.000 25.200
LDED< Double
precision
In conductive status 4.700 37.400 4.700 37.400 4.700 37.400 5.100 25.000
In non-conductive status 4.700 37.400 4.700 37.400 4.700 37.400 4.200 24.100
ANDED< Double
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.500 34.700 4.500 34.700 4.500 34.700 4.000 19.400
In non-
conductive
status
4.500 34.700 4.500 34.700 4.500 34.700 4.100 19.700
ORED< Double
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.700 33.200 4.700 33.200 4.700 33.200 5.000 25.100
In non-
conductive
status
4.700 33.200 4.700 33.200 4.700 33.200 5.000 25.100
LDED>= Double
precision
In conductive status 4.700 37.400 4.700 37.400 4.700 37.400 4.200 13.100
In non-conductive status 4.700 37.400 4.700 37.400 4.700 37.400 4.300 13.100
ANDED>= Double
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.500 34.700 4.500 34.700 4.500 34.700 3.900 19.500
In non-
conductive
status
4.500 34.700 4.500 34.700 4.500 34.700 4.100 19.800
ORED>= Double
pr
ec
ision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.700 33.200 4.700 33.200 4.700 33.200 5.000 25.100
In non-
conductive
status
4.700 33.200 4.700 33.200 4.700 33.200 4.200 18.500
Category Instruction Condition (device) Processing time (s)
Q00UJCPU Q00UCPU Q01UCPU Q02UCPU
Min. Max. Min. Max. Min. Max. Min. Max.