950
APPENDICES
Appendix 1 Operation Processing Time
Basic
instruction
LDE< Single
precision
In conductive status 4.400 20.900 4.400 20.900 4.400 20.900 4.700 11.500
In non-conductive status 4.400 20.900 4.400 20.900 4.400 20.900 4.700 10.900
ANDE< Single
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.200 19.600 4.200 19.600 4.200 19.600 4.300 9.200
In non-
conductive
status
4.200 19.600 4.200 19.600 4.200 19.600 4.400 9.400
ORE< Single
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.200 17.400 4.200 17.400 4.200 17.400 4.600 10.400
In non-
conductive
status
4.200 17.400 4.200 17.400 4.200 17.400 4.400 9.800
LDE>= Single
precision
In conductive status 4.400 20.900 4.400 20.900 4.400 20.900 4.700 12.200
In non-conductive status 4.400 20.900 4.400 20.900 4.400 20.900 4.700 11.800
ANDE>= Single
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.200 19.600 4.200 19.600 4.200 19.600 4.100 6.700
In non-
conductive
status
4.200 19.600 4.200 19.600 4.200 19.600 4.400 7.000
ORE>= Single
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.200 17.400 4.200 17.400 4.200 17.400 4.600 14.000
In non-
conductive
status
4.200 17.400 4.200 17.400 4.200 17.400 4.500 14.300
LDED= Double
precision
In conductive status 4.700 37.400 4.700 37.400 4.700 37.400 4.200 21.000
In non-conductive status 4.700 37.400 4.700 37.400 4.700 37.400 5.100 21.900
ANDED= Double
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.500 34.700 4.500 34.700 4.500 34.700 3.800 17.800
In non-
conductive
status
4.500 34.700 4.500 34.700 4.500 34.700 4.100 18.100
ORED= Double
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.700 33.200 4.700 33.200 4.700 33.200 4.100 23.800
In non-
conductive
status
4.700 33.200 4.700 33.200 4.700 33.200 4.900 25.500
LDED<> Double
precision
In conductive status 4.700 37.400 4.700 37.400 4.700 37.400 5.100 23.500
In non-conductive status 4.700 37.400 4.700 37.400 4.700 37.400 4.200 22.600
ANDED<> Double
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.500 34.700 4.500 34.700 4.500 34.700 4.000 18.800
In non-
conductive
status
4.500 34.700 4.500 34.700 4.500 34.700 4.000 18.700
ORED<> Double
pr
ec
ision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.700 33.200 4.700 33.200 4.700 33.200 5.000 25.200
In non-
conductive
status
4.700 33.200 4.700 33.200 4.700 33.200 4.100 23.400
Category Instruction Condition (device) Processing time (s)
Q00UJCPU Q00UCPU Q01UCPU Q02UCPU
Min. Max. Min. Max. Min. Max. Min. Max.